    • 1、插上電(dian)源插按下霉菌培(pei)養(yang)箱(xiang)的電(dian)源開關,顯示屏所顯示的是培(pei)養(yang)箱(xiang)室(shi)內(nei)的實際溫(wen)度(du)和(he)濕度(du)。
      2、鏈(lian)接加(jia)(jia)(jia)濕(shi)器(qi)(qi)的電(dian)源(yuan),插(cha)頭插(cha)在儀器(qi)(qi)背(bei)面(mian)的電(dian)源(yuan)插(cha)座上(shang),將儀器(qi)(qi)的加(jia)(jia)(jia)濕(shi)管(guan)與加(jia)(jia)(jia)濕(shi)器(qi)(qi)相連,檢(jian)查是(shi)否(fou)緊密連接。給加(jia)(jia)(jia)濕(shi)器(qi)(qi)水箱里加(jia)(jia)(jia)水(參(can)照說(shuo)明書(shu)正確操作)。加(jia)(jia)(jia)濕(shi)器(qi)(qi)若有(you)故障,請按加(jia)(jia)(jia)濕(shi)器(qi)(qi)使(shi)用說(shuo)明書(shu)上(shang)的保修(xiu)點,就近修(xiu)理。
      3、按下(xia)溫(wen)(wen)度(du)(du)(du)按鈕,此時數字(zi)顯(xian)示(shi)即為設(she)定值,旋轉(zhuan)溫(wen)(wen)度(du)(du)(du)調至所需溫(wen)(wen)度(du)(du)(du)值,數字(zi)顯(xian)示(shi)即為培(pei)養(yang)室內(nei)(nei)(nei)(nei)的(de)實(shi)(shi)際溫(wen)(wen)度(du)(du)(du)。例如(ru)培(pei)養(yang)箱內(nei)(nei)(nei)(nei)的(de)實(shi)(shi)際溫(wen)(wen)度(du)(du)(du)比設(she)定溫(wen)(wen)度(du)(du)(du)小,加(jia)熱(re)(re)指(zhi)示(shi)燈亮(liang),加(jia)熱(re)(re)器(qi)開始加(jia)熱(re)(re);如(ru)霉菌培(pei)養(yang)箱內(nei)(nei)(nei)(nei)的(de)實(shi)(shi)際溫(wen)(wen)度(du)(du)(du)比設(she)定溫(wen)(wen)度(du)(du)(du)大,制冷指(zhi)示(shi)燈亮(liang),制冷系(xi)統開始制冷;如(ru)加(jia)熱(re)(re)指(zhi)示(shi)燈與制冷指(zhi)示(shi)燈均暗,則(ze)(ze)培(pei)養(yang)箱處(chu)于恒溫(wen)(wen)狀態。、當溫(wen)(wen)度(du)(du)(du)設(she)定好之后,不(bu)要將控溫(wen)(wen)旋鈕來回(hui)多次旋轉(zhuan),壓縮機啟動頻繁,則(ze)(ze)會造(zao)成壓縮機出(chu)現過載現象(xiang),直接(jie)影響壓縮機的(de)使用(yong)壽命。 在(zai)使用(yong)溫(wen)(wen)度(du)(du)(du)較(jiao)低時,應定期(qi)清理掉(diao)箱內(nei)(nei)(nei)(nei)底(di)部積水盤內(nei)(nei)(nei)(nei)的(de)積水。濕(shi)度(du)(du)(du)長期(qi)不(bu)用(yong)時,請將盒內(nei)(nei)(nei)(nei)水倒(dao)盡。
      4、濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)調節:選擇濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)設定按(an)鈕,當前數字顯(xian)(xian)(xian)示(shi)(shi)(shi)即為(wei)設定值(zhi)(zhi),旋轉濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)調至(zhi)所(suo)需濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)值(zhi)(zhi),松開即可,此時數字顯(xian)(xian)(xian)示(shi)(shi)(shi)即為(wei)霉菌培(pei)(pei)養(yang)箱(xiang)內(nei)的(de)實際(ji)濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)。當培(pei)(pei)養(yang)室內(nei)的(de)實際(ji)濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)比設定的(de)濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)小時,此時加濕(shi)(shi)(shi)(shi)(shi)對(dui)培(pei)(pei)養(yang)室內(nei)加濕(shi)(shi)(shi)(shi)(shi),加濕(shi)(shi)(shi)(shi)(shi)指(zhi)示(shi)(shi)(shi)燈亮;當培(pei)(pei)養(yang)室內(nei)的(de)實際(ji)濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)比設定的(de)濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)值(zhi)(zhi)大(da)時,此時加濕(shi)(shi)(shi)(shi)(shi)器(qi)(qi)停止工(gong)作,加濕(shi)(shi)(shi)(shi)(shi)指(zhi)示(shi)(shi)(shi)燈滅。由于濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)傳感(gan)器(qi)(qi)長(chang)時間處(chu)于高(gao)濕(shi)(shi)(shi)(shi)(shi)狀態,便(bian)會(hui)形成結(jie)露即濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)顯(xian)(xian)(xian)示(shi)(shi)(shi)值(zhi)(zhi)會(hui)居(ju)高(gao)不下。如果需要準確的(de)濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)顯(xian)(xian)(xian)示(shi)(shi)(shi)值(zhi)(zhi),那么(me)應該關機后,將箱(xiang)門打(da)開,讓濕(shi)(shi)(shi)(shi)(shi)度(du)(du)(du)傳感(gan)器(qi)(qi)處(chu)于室溫(wen)中,自然(ran)干燥后,可再繼續使用。
      5、機器運轉出現故障(zhang)(控溫失靈,不(bu)加熱(re)或不(bu)制冷(leng))馬上切斷電源(yuan),檢查機背部裝的保險盒,2A:為(wei)制冷(leng)加熱(re)負(fu)載保險絲(si)盒,8A:為(wei)控制電源(yuan)保險絲(si)盒。看看保險絲(si)是否完好,檢查相應的部位。
      6、如箱內不需(xu)殺(sha)菌時(shi),應(ying)將面(mian)板(ban)上的殺(sha)菌開關(guan)置于“關(guan)"的位置。
      7、當儀器(qi)在停止使(shi)用時(shi),應拔掉電源插(cha)頭。
      8、搬(ban)運時小心,搬(ban)運時與水平面的夾(jia)角不(bu)得(de)小于45°
      9、為(wei)了保持設(she)備的美觀(guan),不準用酸或堿及其它腐蝕(shi)性物品來擦表面,箱(xiang)內可以用干布定期擦干。